Body Dimension: (EXTERNAL) |
Length | 10,000mm |
Width | 2,600mm |
Height fr. floor | 2,500mm |
Frame Construction | All welded steel construction to specification ST 37-2 or equivalent |
Chassis Extension | 1100mm length extension to be connected with complete bolt and nuts to the original chassis. |
External Cladding | Made of 3mm GRP sheet in white finish coated |
Internal Cladding/Insulation | Left and right side wall of the body is insulated with 50mm /PU foam + 12mm plywood, 6mm MDF plywood and covered with 0.5mm and A-210 PORTLAND fabric. |
Ceiling | 150mm draft ceiling is insulated with 50mm/PU foam and covered with decorated wood. |
Flooring | Floor is made up of 100mm panel and to be covered by washable vinyl flooring. (W500 x H80mm will be cut for the cable access.) |
Side Cladding | The external cladding is made 3mm aluminum plain sheet. This is divided as a side board for storage purposes. Locks, hinges, holder and other accessories of the door will be provided. |
Side Door(s) | One (1) standard door will be provided. A main entrance/exit with sliding manual stairs will be provided. Locks, hinges, holder and other accessories of the door will be provided. |
Door extension | One (1) door access at extension room with manual sliding stairs. |
Rear Door | One (1) rear double leaf door that made of MS tube and plate. Locks, hinges, holder and other accessories of the door will be provided. Sliding stair will be provided. |
Access Door/windows | Doors are provided with complete locks, hinges and to be driven by the gas spring. (see attached drawing) |
Roof Reinforcement | Re-enforcement will be made as per the part which in need to fix. |
Body Edges | It will be covered with aluminum angles and trim. |
Ladder & Rails | Made up of stainless steel pipe and it is fixed on rear side. Rails will be fixed on the top. |
Hydraulic Jack | Four (4) pcs hydraulic jack with the complete accessories will be fixed on under the body. Two (2) jacks on the front and two (2) jacks on the rear side. |
PTO & PUMP | 60-80cc capacity, maximum pressure of 280 bars and continues pressure is 190 bars will be provided. |
Control Lever | Four levers will be provided. One for front jack, one for rear jack, one for sliding platform jack. (Note: Remote control will be installed as per customer request.) |
Hydraulic Hose | All hoses will be mounted under chassis and made of rubber. |
III. OB ROOM ACCESSORIES DETAILS: |
Other Accessories | Four (4) 2kg fire extinguisher |
Air deflector (Note: To be re-confirmed by the client.) |
Racks (Note: Dimension and design must be decided by the client.) |
Tables (Note: Dimension and design must be decided by the client.) |
IV. ELECTRICAL SYSTEMS: |
Lights | Original Rear lights, backing lights, and rear signal lights will be utilized. |
Four (4) 220V tube lights and twelve (12) 220V dimmable ceiling lights with will be provided. |
Six (6) spot lights will be provided. Two (2) on the rear, left and right side. |
Wiring | Supply wiring will be added for the mechanical and electrical accessories. |
Supply | o Supply from Shoreline (external source) through 3-pole CEE-plug |
o Original battery will be utilized. |
Safety | o One (1) distribution box with all the breakers on one of the right hand side cabin inside the working area will be provided |
o One (1) master power switch will be provided (Generator, Shoreline, & Off) |
o One (1) Earth grounding block will be provided to connect to the chassis/ground |
Shoreline | One connector will be provided for external source |
Painting | One (1) coat of epoxy primer and Two (2) coats of finish paint for the body. One (1) coat/s of Finish paint ( color must be decided by client) |